Quick Answer

A Lost leg of service means one of the two live feeds entering your home has failed, so roughly half of your circuits go dead and every 240-volt circuit stops working properly. The fault can sit with the Electric utility (service provider), in the Meter base / meter pan, or in your panel. A pro measures voltage leg by leg to find the dividing line.

See The Full Emergency Electrician Page

What Does Losing A Leg Of Power Actually Mean?

A typical home supply arrives as two live legs. Each feeds roughly half of the circuits in the panel, and together they feed every 240-volt circuit — the dryer, range, air conditioning and well pump among them. A Lost leg of service means one of those feeds has failed between the street and your breakers, while the other keeps working.

That split makes the fault confusing: the home is neither fully on nor fully off. Lights in one part behave normally, sockets in another are dead, and appliances needing both legs stop, hum or run weakly. The pattern maps onto which leg each circuit sits on.

What Are The Signs One Leg Has Failed?

Is This Happening Right Now?

One free call connects you with a local pro who can check it safely — day or night.

Call (800) 555-0100

The clearest sign is a clean divide: about half the circuits dead at once, with no single breaker tripped, while the rest of the home works normally. Several circuits failing together in that pattern puts the problem upstream of the individual breakers — in a leg, not in one room's wiring.

Why Do Some Rooms Work Normally While Others Are Dead?

Because the panel divides its circuits between the two legs. Breakers in the Electrical panel / breaker panel alternate between legs down each side, so a failed leg takes out a scattered pattern of rooms rather than one tidy half of the house. A homeowner ringing an emergency electrician in Acampo about sockets dead in the kitchen, a bedroom and the garage at the same moment is describing that pattern.

Why Do Large Appliances Stop Or Struggle On One Leg?

Large appliances draw from both legs at once, so losing one leg removes half of what they are built to run on. Heating appliances produce little or no heat, and motor-driven ones — air conditioning, a well pump, a dryer motor — may hum, start slowly or refuse to start. A motor on reduced voltage draws harder and heats faster, so struggling equipment should be switched off, not coaxed.

Why Might Dead Circuits Glow Faintly Or Flicker Back?

A dead leg can pick up a faint feed through a large appliance still switched on: power crosses inside it from the live leg to the dead one, then reaches the dead circuits at reduced strength. Lights may glow dimly and brighten or fade as that appliance cycles. It looks like recovery; it is not. Switching large appliances off removes the faint feed and confirms the leg is still down.

How Can You Tell Whether It Is The Utility Or Your Panel?

Only measurement settles it, because the same symptoms come from faults on either side of the meter. A pro measures with a Multimeter at the Service entrance conductor and works downstream: what arrives from the Service drop, what passes through the Meter base / meter pan, what the Main breaker / main disconnect hands to the panel, and what each Bus bar then carries. Where a healthy reading turns into a missing leg is the dividing line.

If a leg is already missing where the supply enters, the fault belongs to the Electric utility (service provider) — a failed connection or damaged conductor on its side — and the pro passes the readings on so the utility crew knows what to look for. If both legs arrive correctly but one is missing past the main breaker, the fault is in the home's equipment: a failing main breaker, a heat-damaged bus connection or a loose lug. A caller asking an emergency electrician in Acton or an emergency electrician in Adelanto who fixes it should expect that measured answer, not a guess.

What Causes A Leg To Fail In The First Place?

Heat and weather cause most cases. A Loose connection on one leg arcs and overheats under load until it fails open, and Corrosion (bus bars, lugs, outdoor equipment) raises resistance at a joint the same way, slowly cooking it. Storm damage to service equipment can tear a conductor at the mast, Water intrusion in an outdoor meter base corrodes the jaws gripping the meter, and a Lightning surge can damage a main breaker so one side no longer carries current.

Age plays its part: connections loosen over years of heating and cooling cycles, which is why Torqueing panel connections and a Thermal imaging / infrared scan under Load testing appear in a thorough check — a failing joint runs hot long before it runs dead, as an emergency electrician in Agoura Hills called out after a storm often finds.

What Should You Switch Off While One Leg Is Down?

Switch off every large appliance until the leg is restored: dryer, range, air conditioning, water heater, well pump and any EV charger circuit. Motors starved of voltage overheat, and appliances spanning both legs create the faint backfeed that makes dead circuits flicker. Leave lighting breakers as they are, avoid a Space heater load on the surviving leg, and do not reset anything repeatedly.

Safe isolation / de-energising still governs any work at the panel: the surviving leg is live, and the dead leg can become live without warning if the utility restores its side. Guidance for an emergency electrician in California follows CSLB requirements, and an emergency electrician in Florida works under DBPR rules, but the safety order is the same in both states.

What Affects The Cost Of Fixing A Lost Leg?

Only the factors can be stated honestly — the figure depends on which side of the meter the fault sits on and what the heat has damaged. A utility-side fault is the utility's repair, so the homeowner's cost may be limited to the diagnostic visit. On the home's side, a failed main breaker is contained; a heat-damaged bus or meter base is larger, and damage spread into the panel can lead toward Panel upgrade / service upgrade work. Permit and inspection requirements through the Local building / permit department, and whether the utility must disconnect the service, also shape the total. Any charge is agreed with the independent pro before work starts.

When Should You Call About A Lost Leg?

Call as soon as the pattern shows — half the home dead and large appliances failing together is not a wait-and-see fault. Call immediately, and keep away from the panel, if it buzzes, runs hot, sparks or smells of burning. One free call connects you with an independent local pro with 20+ Years Of Experience who can typically arrive in 30–60 minutes, measure both legs through the service, and say plainly whether the fix belongs to the utility or to your equipment.

Emergency Electrician Near You

This guide applies everywhere we serve. These city pages show local facts, reviews and coverage:

Lost Leg Of Power FAQs

Still not sure what is happening at your home? Call and describe it. A real person answers, day or night, and the call is free.

Call (800) 555-0100
Why Is Half My House Without Power While The Other Half Works Normally?
Because the panel splits its circuits between two incoming legs, and only one of them has failed. Breakers alternate between legs down each side of the panel, so the dead rooms look scattered — a bedroom here, part of the kitchen there — rather than one neat half of the house. The surviving leg keeps its circuits fully normal, which is why the fault is easy to mistake for several separate problems until someone maps which circuits died together.
Why Have My Dryer, Oven And Air Conditioning All Stopped Together?
Those appliances are built to draw on both legs together, so a missing leg removes half their supply in one stroke. Heating elements produce little heat, and motors — the dryer's drum motor, the air conditioner's compressor — hum, strain or refuse to start. A motor kept running on reduced voltage overheats quickly and can be damaged by an electrical fault that began somewhere else entirely. Switch them off at the appliance until the leg is restored and tested.
Why Do Lights On The Dead Side Of My House Glow Faintly Sometimes?
Usually because power is leaking across from the live leg through a large appliance that is still switched on, reaching the dead circuits at reduced strength. As that appliance cycles, the faint feed rises and falls, so lamps brighten and dim as if power were returning. It is a backfeed, not a recovery. Switching the large appliances off normally ends the glow, and only a voltage reading at the panel confirms when the leg is genuinely back.
How Is A Lost Leg Different From A Lost Neutral?
The symptoms differ in a way a homeowner can spot. With a lost leg, one set of circuits is simply dead while the other set behaves completely normally. With an Open neutral / lost neutral, almost nothing is fully dead — instead voltages swing as appliances switch on, so some lights flare brighter than normal while others dim. Brightening lights are the warning sign of the neutral fault, and both faults need a pro's measurements rather than trial and error.
Should I Turn Off Large Appliances Until The Missing Leg Is Restored?
Yes — turn off the dryer, range, air conditioning, water heater, well pump and any charger until the supply is whole again. Motors strain and overheat on reduced voltage, and appliances spanning both legs feed power backwards into the dead circuits, which muddies every symptom. Ordinary lights on the working leg can stay on. Leave the panel itself alone: repeated switching clears nothing, and the dead leg can come back without warning.
Can Running On One Leg Damage My Appliances Or Motors?
It can, and motors are the most exposed. A compressor, pump or fan motor designed for full voltage draws more current and runs hotter when its supply drops, and its protection may not trip before heat builds up in the windings. Heating appliances mostly just underperform, but electronics fed through a faint backfeed see unstable voltage, which they are not built for. Switching large equipment off early is cheap protection against a second repair bill.
Who Is Responsible For Fixing A Lost Leg — The Utility Or A Pro?
It depends entirely on where measurement finds the break. If a leg is missing in the supply arriving at your meter, the fault sits on the utility's side — its drop, its connections — and the utility repairs it. If both legs arrive at the meter but one disappears inside your panel or meter base, the equipment is yours and a local pro does the work. A pro's readings draw that line clearly for both parties.
Why Did One Leg Fail Right After A Storm When Everything Worked Before?
Storms attack the supply at its exposed points: wind works connections loose at the mast and the drop, falling branches tear at conductors, and rain finds its way into outdoor equipment that was already corroded. A joint weakened over years often survives ordinary weather and lets go under storm movement and load. Flicker during the storm, then a clean half-outage afterwards, fits a conductor or connection that failed under that stress rather than a fault inside one room.
Can A Faulty Main Breaker Look Exactly Like A Utility Outage On One Leg?
Yes — from the rooms, the two look identical, because in both cases one leg never reaches the circuits. A main breaker can fail on one side while still passing the other, leaving its handle looking on and the panel half live. The difference only shows in measurements: voltage present at the breaker's incoming side but absent on its outgoing side convicts the breaker, while voltage already missing at the service entrance points outward to the utility.
What Affects What I Will Pay To Get A Lost Leg Fixed?
Start with which side of the meter the fault sits on, because a utility-side failure is the utility's repair. On your side, the factors are what failed — a main breaker, a meter base, a damaged bus — and how far the heat travelled into conductors and neighbouring connections before the leg let go. Access to the service equipment, whether the utility must disconnect for the work, and local permit and inspection steps also count. Any charge is agreed before work starts.

Reviewed By Hamza

Master Electrician & Emergency Power Restoration Specialist

Hamza is a master electrician and emergency power restoration specialist with extensive field experience resolving critical residential and commercial electrical hazards across California, Florida, and Texas. He specializes in thermal arc-fault diagnostics, emergency panel replacements, storm-damaged service mast repairs, and whole-home surge mitigation to protect properties from electrical fires and extended outages.

Updated October 30, 2026

Need Emergency Electrician Help Near You?

If your power problem cannot wait, one free call connects you with a local pro — 24/7.

Call (800) 555-0100

Free call · Open now · 24 hours a day, 7 days a week

Related Emergency Guides

See All Guides